Frequency inverter, 4kW, 380V- 480V, 9,0A, IP20, including operation panel

  • V/f Control, Sensorless Vector Control selectable
  • PID-Control for expanded Proces Control
  • High Torque within complete motor Speed range
  • 0,1-400Hz output frequency (1000Hz model on request )
  • 1-15kHz base frequency
  • Input Voltage range -15% bis +10%
  • Fault history: last 5 faults
  • Analog input 0 to +10Vdc / -10 to +10Vdc
  • 150% torque at 0,5Hz
  • Protection degree: IP20 , UL Typ 1 (Optional)
  • Torque Boost  manual/automatic
  • Input signal PNP/NPN selectable
  • Control and parameter set for second motor
  • Brake chopper for dynamic braking as standard
  • Automatic setting : vector measurment of the motor  and Autotuning
  • Bult-in communication RS485 (LS Bus / Modbus RTU)
  • Fan with On/Off-control, easy to replaceRemote control with external keypad and RJ5-cable (Option) 
  • Enhanced functions:
  • Sleep & Wake-up function
  • Energy saving
  • KEB-protection (saving of kinetic energy)
  • Leckage current reduction
  • Software(Drive View) for monitoring and parameter setting via computer

Properties "Frequency Inverter LS 040-IG5A-4"
Manufacturer: LS
Performance: 4,0 kW
Protection class: IP20
Series: IG5A - the fast one
Tension: 3 x 400 V

Accesories

Motor connection cable shielded 4 x 1.5 mm²
EMC-optimized cable between frequency converter and motor, low-capacity, double shielded. TheShielding consists of an aluminum-clad foil winding combined with tinned copper braid. Technical specifications:Classification ETIM 5: ETIM 5.0 Class-ID: EC000057ETIM 5.0 Class Description: Power cableClassification ETIM 6: ETIM 6.0 Class-ID: EC000057ETIM 6.0 Class Description: Power cableCore identification code: colored according to HD 308 S2 VDE 0293-308Conductor structure: Fine wire according to VDE 0295 class 5 / IEC 60228 class 5Minimum bending radius:Occasionally moved: 15 x outer diameterFixed installation: 4 x outer diameterNominal Voltage: U0 / U: 600/1000 VTest Voltage: wire / wire: 4 kVCore / screen: 4 kVTemperature range: Moving: -5 ° C to + 70 ° CFixed installation: -40 ° C to + 70 ° CPVC outer sheath: transparentCable diameter about 11.4 mmPlease select the cable length.The cables are made to order. A withdrawal or withdrawal from the purchase is excluded!All product photos are non-binding examples!

From €3.81*
Potentiometer- 0-10KΩ
Potentiometer, 0-10KΩ, suitable for control cabinet mounting. This stepless rotary potentiometer can be used for the complete range of LS frequency inverters. The potentiometer can be connected via screw terminals, no soldering is required. Suitable for installation in the control cabinet.

€25.36*
Control cable shielded 7 x 1.0 mm²
Suitable for frequency inverters CPR performance class: Eca, conductor material: Cu, bare conductor class: class 5 = finely stranded, core insulation: PVC TI1 stranding element: core, sheath material: PVC YM2 sheath color: gray RAL 7001, flame retardant : VDE 0482-332-1-2 / IEC 60332-1-2 Maximum permissible conductor temperature: 70 ° C Perm. External cable temperature fixed: -40 - +70 ° C Perm. Outside cable temperature, in motion -5 - +70 ° C bending radius, fixed installation: 6 x Ø, bending radius, moving: 20 x Ø nominal Voltage Uo: 300 V, nominal Voltage U: 500 V core identification: green -yellow + digits cable diameter approx. 10.1 mm Please select the cable length and the equipment. All product photos are non-binding examples! Technical changes reserved.

From €10.19*
LS IG5A-operating panel
Control panel with LCD display for IG5A. Dimensions: 273mm x 127mm x 79mm (HxWxD) Optionally with 2m or 5m connection cable. All product photos are non-binding examples!

From €47.23*
EMC-Filter-4kW
EMC filter for frequency inverters up to 4 kW motor power, external / undercounter. 12 A, 3 phase, 480V / 275V, 50-60-Hz, 1.1kg, All product photos are non-binding examples!

€153.83*
Foot switch with metal housing F1-AU0-10V
Rated operational Voltage Ue 12-26 V DC Utilization category DC-13 Ue / Ie 12-26 DC / 0.2 A according to IEC / EN 60947-5-2 Voltage output (control range) 0- 10 V DC short-circuit protection device switching element permanent short-circuit u. overload-proof, clocking Protection class IIIM UB GND RL U-OUT U-OUT housing AL die-cast; Lid die-cast aluminum actuating elements foot pedal (PA) ambient temperature -30 ° C to +80 ° C contact type PNP closer, teachbar from 0.1 - 5.9 mm switching force pedal approx. 10 N (center of pedal) Mechanical life 10 x 106 switching cycles and switching frequency max. 50 / min; Fastening 2 M8 screws connection type screw connections (M3.5) number of connections 4, conductor cross sections solid 0.5 - 1.5 mm2 stranded wire with ferrule 0.5 - 1.5 mm2, cable entry 1 x M20 x 1.5 weight 1.5 kg, Protection class IP65 according to IEC / EN 60529 drawing ID: Z030  

€237.38*