Frequency inverter LS008M100

€157.41*

Delivery time about 3-4 business days

Product number:
66430004
Shipping fees:
Item + packaging
Product information " Frequency inverter LS008M100"

Frequency inverter , 0.75 kW, 230V, 4.2A, IP20, EMC filter integrated

- EMC filter C2
- Potentiometer for speed control
- Attachment to mounting plates or DIN rail
- Side-by-side installation possible (2 mm distance between the FU)
- Easy connection via RJ45 port
- Standard IO: 3x DI, 1x DO, 1x AI (0-10V), 1x AO (0-10V)
- Brake chopper for 1.5kW and 2.2kW versions
- Overload capacity 150% for 1 min
- Programming with DriveView9 operating software via RJ45 connection on the M100
(Advanced only! The standard version does not have an RJ45 interface! Please select version.)

Excerpt from spec. Features:
- DC braking
- Jog operation
- 3-wire operation
- Dwell operation (dwell time operation)
- Slip compensation
- PID control
- Energy saving operation
- Speed search
- Automatic restart

 



0.75kW frequency converter , single-phase (1 x 220 / 230 / 240 V)

Properties " Frequency inverter LS008M100"
Manufacturer: LS
Performance: 0,75 kW
Protection class: IP20
Series: M100 - the new compact
Tension: 1 x 230 V

Accesories

Control cable shielded 7 x 1.0 mm²
Suitable for frequency inverters CPR performance class: Eca, conductor material: Cu, bare conductor class: class 5 = finely stranded, core insulation: PVC TI1 stranding element: core, sheath material: PVC YM2 sheath color: gray RAL 7001, flame retardant : VDE 0482-332-1-2 / IEC 60332-1-2 Maximum permissible conductor temperature: 70 ° C Perm. External cable temperature fixed: -40 - +70 ° C Perm. Outside cable temperature, in motion -5 - +70 ° C bending radius, fixed installation: 6 x Ø, bending radius, moving: 20 x Ø nominal Voltage Uo: 300 V, nominal Voltage U: 500 V core identification: green -yellow + digits cable diameter approx. 10.1 mm Please select the cable length and the equipment. All product photos are non-binding examples! Technical changes reserved.

From €10.19*
Right/left switch, potentiometer for FU
Right-left rotation switch with potentiometer in a plastic housing Switch latching. External Frequency inverter Steering. Optionally without or with 1m, 3m or 5m cable (wired). Please select version. All product photos are non-binding examples!

From €89.79*
Motor connection cable shielded 4 x 1.5 mm²
EMC-optimized cable between frequency converter and motor, low-capacity, double shielded. TheShielding consists of an aluminum-clad foil winding combined with tinned copper braid. Technical specifications:Classification ETIM 5: ETIM 5.0 Class-ID: EC000057ETIM 5.0 Class Description: Power cableClassification ETIM 6: ETIM 6.0 Class-ID: EC000057ETIM 6.0 Class Description: Power cableCore identification code: colored according to HD 308 S2 VDE 0293-308Conductor structure: Fine wire according to VDE 0295 class 5 / IEC 60228 class 5Minimum bending radius:Occasionally moved: 15 x outer diameterFixed installation: 4 x outer diameterNominal Voltage: U0 / U: 600/1000 VTest Voltage: wire / wire: 4 kVCore / screen: 4 kVTemperature range: Moving: -5 ° C to + 70 ° CFixed installation: -40 ° C to + 70 ° CPVC outer sheath: transparentCable diameter about 11.4 mmPlease select the cable length.The cables are made to order. A withdrawal or withdrawal from the purchase is excluded!All product photos are non-binding examples!

From €3.81*
LS Smart Copier
Smart copier for S100, IS7, M100, H100, G100 When using the Smart Copier, the inverter does not require a power supply. The Run LED flashes during normal operation. The error LED flashes if there are problems (e.g. communication errors) occur. Parameters can easily be copied/loaded from the inverter into the Smart Copier using the control panel and vice versa. Firmware and parameters stored in the Smart Copier can be exported to both the inverter I/O and the Control section can be downloaded. Firmware can be downloaded from a PC via a USB cable become. R45 cable (included with purchase of Smart Copier). All product photos are non-binding examples! Technical changes reserved.

€1,234.68*
Right/left switch, emergency stop for FU
Right-left rotation switch with emergency stop in a plastic housing Switch not latching. External Frequency inverter Steering. Optionally with 1m, 3m or 5m cable (wired). Please select version. All product photos are non-binding examples!

From €171.65*
Right-left-turn switch for VFD
Right-left rotation switch with potentiometer and emergency stop in a plastic housing. Switch not latching. External frequency converter control. Potentiometer connection solder contacts 1 NO contact each for left and right rotation Housing dimensions in mm (WxHxD): 160x80x55 Color: similar to RAL7035 Potentiometer: 2.2k / 2W, rotation angle 270 °, rotary knob : 32mm cable gland: M16, clamping range 5-10mm degree of protection: IP65, for connection in the control circuit Optionally without or with 1m, 3m or 5m cable (wired). Please choose version. All product photos are non-binding examples!

From €382.79*
LS M100 remote display
External control panel for installation in the control cabinet for M100 series. Optionally with 2m, 3m, or 5m connection cable. The parameters stored in the external control panel can be changed in the converter of the same series can be copied. All product photos are non-binding examples! Technical changes reserved.

From €49.65*
LS M100 / G100 USB-cabel
USB cable for M100 / G100. (RJ45 > USB) Programming with DriveView7 operating software via RJ45 connection on the M100 / G100. With M100 only the Advanced version! The standard M100 does not have an RJ45 interface!

€33.38*
Potentiometer- 0-10KΩ
Potentiometer, 0-10KΩ, suitable for control cabinet mounting. This stepless rotary potentiometer can be used for the complete range of LS frequency inverters. The potentiometer can be connected via screw terminals, no soldering is required. Suitable for installation in the control cabinet.

€25.36*
Foot switch with metal housing F1-AU0-10V
Rated operational Voltage Ue 12-26 V DC Utilization category DC-13 Ue / Ie 12-26 DC / 0.2 A according to IEC / EN 60947-5-2 Voltage output (control range) 0- 10 V DC short-circuit protection device switching element permanent short-circuit u. overload-proof, clocking Protection class IIIM UB GND RL U-OUT U-OUT housing AL die-cast; Lid die-cast aluminum actuating elements foot pedal (PA) ambient temperature -30 ° C to +80 ° C contact type PNP closer, teachbar from 0.1 - 5.9 mm switching force pedal approx. 10 N (center of pedal) Mechanical life 10 x 106 switching cycles and switching frequency max. 50 / min; Fastening 2 M8 screws connection type screw connections (M3.5) number of connections 4, conductor cross sections solid 0.5 - 1.5 mm2 stranded wire with ferrule 0.5 - 1.5 mm2, cable entry 1 x M20 x 1.5 weight 1.5 kg, Protection class IP65 according to IEC / EN 60529 drawing ID: Z030  

€237.38*
Single-phase mains choke 20 A for M100 series
Rated current=20 A @ 40°C, rated voltage=230 VAC / 1ph Inductance=2x 1.49 mH, short-circuit voltage=8%, nominal frequency=50/60 Hz, Dimensions (LxWxH)=95 x 96 x 105 mm, weight=approx. 32. kg, customs tariff no.=85045000, Overload capacity=2 times the rated current when switched on, then 1.5 times for 1 minute. Limitation of harmonics, protective device for unthrottled compensation systems, Increasing interference immunity, reducing voltage dips and current peaks, Suitable for operating motors directly on the mains.

€240.64*
Single-phase mains choke 16 A for M100 series
Rated current=16 A @ 40°C, rated voltage=230 VAC / 1ph Inductance=2x 1.8 mH, short-circuit voltage=8%, nominal frequency=50/60 Hz, Dimensions (LxWxH)=80 x 96 x 88 mm, weight=approx. 2.8 kg, customs tariff no.=85045000, Overload capacity=2 times the rated current when switched on, then 1.5 times for 1 minute. Limitation of harmonics, protective device for unthrottled compensation systems, Increasing interference immunity, reducing voltage dips and current peaks, Suitable for operating motors directly on the mains.

€218.57*
Single-phase mains choke 11 A for M100 series
Rated current=11 A @ 40°C, rated voltage=230 VAC / 1ph Inductance=2x 2.65 mH, short-circuit voltage=8%, nominal frequency=50/60 Hz, Dimensions (LxWxH)=84 x 90 x 90 mm, weight=approx. 2.0 kg, customs tariff no.=85045000, Overload capacity=2 times the rated current when switched on, then 1.5 times for 1 minute. Limitation of harmonics, protective device for unthrottled compensation systems, Increasing interference immunity, reducing voltage dips and current peaks, Suitable for operating motors directly on the mains.

€185.91*